DSX-1000A
Read and saved these instruction
Thank you to choose the DSX air purifier. Please read the manual carefully before using the product. In order to use the air purifier correctly, please keep the manual properly for reference.
CATALOGUE
l Safety instructions
l Matters needing attention
l Product introduction
l Name of component
l Operating instructions
l Introduction of sensors function
l The mounting method
l Cleaning and maintenance
l Failure analysis
Before your first use, please refer to these safety instructions for safe use. Remember that the warranty is restrictive and only applies when used correctly according to the instructions. The manufacturer will not be liable for any damage or loss caused by the user's failure to strictly comply with the instructions. This product complies with the maximum allowable concentration of ozone of 0.050 parts per million by volume (ppmv) in a 24-h period.
1. Please place the product in a place with free air circulation, at least 20cm away from other objects.
2. Do not place or rely on soft furniture, such as bedding or curtains.
3. Do not put this product near heat sources, such as electric heating tablets, oven or induction cooker, gas canister and other inflammable products.
4. Children are not allowed to play or use the machine in case of accidents.
5. Please use the original power cord provided by us, only single-phase alternating current can be used, otherwise it may cause fire, electric shock and other accidents.
6. If the power cord and plug are damaged or the plug is too loose after insertion, please do not use it. If the power cord is damaged, it must be replaced by the technical service center or repair technicians to avoid causing fire, electric shock, short circuit and other dangerous accidents.
7. Do not touch, damage, excessively bend, stretch, twist, tie, press or squeeze the power cord, otherwise it may cause fire, electric shock, short circuit and other accidents.
8. When replacing the filter element, remove or clean the machine, turn off the power and unplug the power cord. When unplugging, hold onto the plug.
9. Do not pull out the plug when your hands are wet, which may cause electric shock and injury.
10. If it is not used for a long time, the plug must be pulled out, otherwise the insulation performance will decline, which will lead to electric shock and leakage, fire and other accidents.
11. Contact technical service center for repairs.
12. Please unplug or disconnect the appliance from the power supply before servicing.
WARNING – To reduce the risk of fire or electric shock, do not use this fan with any solid-state speed control device.
WARNING – Skin or eye damage may result from directly viewing the light produced by the lamp in this apparatus. Always disconnect power before relamping or servicing. Replace lamp with lamp SM-T8-UVC-15W.
1. Do not insert foreign body in the air inlet and outlet, otherwise electric shock and other accidents may be caused.
2. Please do not use the machine in the bathroom or other places with high humidity. It is easy to be affected by damp, or it will cause an accident or malfunction.
3. Do not allow this machine to inhale combustible gas or sparks caused by cigarette, incense, etc., or it may cause fire and other accidents.
4. Do not wipe the machine with gasoline or paint thinner, and do not spray insecticide on the machine, otherwise it may cause cracks, electric shock, fire and other accidents.
5. Do not use this product when using spray insecticide indoors. Because the inside of the machine can accumulate pharmaceutical ingredients, when released from the tuyere, can affect health.
6. When using with combustion apparatus, ventilation should be carried out. Air purifiers do not remove carbon monoxide, which can be toxic if air is not changed.
7. When replacing the UV lamp, please pay attention to disconnect the power supply completely.
DSX series air purifier adopts HEPA filter with the highest safety in the market to filter the particles in the air. Under the action of the low noise and high wind speed fan of the air purifier, the indoor air is filtered from the inlet end through the primary filter and then inhaled into the fan chamber. Under the influence of the fan pressure, the air is sent to the static pressure line, and the air is filtered through the HEPA filter screen After filtration and adsorption, clean air is sent into the room. This circulation ensures that the air reaches an ideal clean state.
l HEPA filter
H13 medical grade HEPA filter screen can quickly filter and absorb particles from small to 0.3 μ m in the air. For PM2.5 particles, the one-time filtration efficiency can reach 99.99%, without secondary pollution. It is the safest treatment method for particles in the current market.
l Pre-filter
G4 non-woven fabric composite activated carbon pre-filter can effectively remove the large particles in the air.
l UV lamp
This product adopts ozone-free lamp tube, which can effectively kill all kinds of harmful bacteria in the air.
l Micro switch
The air purifier is equipped with a safety protection switch, which is respectively installed on the metal plate frame contacted behind the front cover plate and on the metal plate frame above the right HEPA filter.
When opening the front cover plate or removing all HEPA filters, the air purifier will automatically power off to avoid exposure to ultraviolet light when opening the cover plate.
l Interface description
l Function introduction
Lock: Child lock status indication & Unlock password input button
After successful unlocking or setting, if there is no operation for 5 minutes, the system will be automatically locked, and all functions cannot be touched to change expect the time setting.
:Unlocked
:Locked
UV: UV status indication & UV ON/OFF
:UV not working
:UV working
Run mode: Air purifier working state indication & Air purifier "Manual" and "Automatic" mode switching
:The air purifier is in “Manual” operation
:The air purifier is in “Automatic” operation
Timing: Timing and other parameter setting
:The air purifier in “Standby” or “Manual”
:The timing function of air purifier is in effect
Time: Time display, long press clock area (not the week area) can change the time
TVOC & PM2.5 & CO2: These three circles show real-time concentrations of TVOC, PM2.5 and CO2.
According to the different concentration ranges collected, the colors of the corresponding outer rings will be displayed as green, yellow and red, respectively.
Temp: Real time display of room temperature
Humi: Real time display of room humidity
Fan: You can touch it to adjust the fan speed
Fan speed: Fan current speed display
(Stop )
(Low speed)
(Medium speed)
(High speed)
Filter life: Real time display filter life
ON/OFF: Air purifier ON & OFF button
Timing parameter setting
In this interface, automatic switch on and off and duty time can be set.
In the interface above, you can set which days of the week you need to be on duty and the working period of each day.
After setting the timing time, click the "save all setup" button to save all the parameters.
All timing is off by default at the factory.
Please note that after setting and turning on the timing function, when the air purifier is in the “Automatic” mode, it will automatically detect the timing setting every minute. When it detects that it is not in the set timing or duty time, it will automatically stop running, that means, it will shut down automatically. And next time, it will start automatically according to the set duty time.
Pass word setting
Click the line area shown by the red arrow, and the keyboard will pop up. At this time, enter the password you want to modify. After entering the password, click enter to complete the new password setting. At this time, click the button shown by the green arrow to save the new password.
Replace the filter element with a new one
After replacing the new filter element, please click the "new filter" button to recalculate the filter element life.
After power-on for the first time, the screen will display the power-on animation, and then enter the following screen display interface, After the power switch is turned on, the air purifier will automatically enter the “Manual” mode:
As shown in the figure above, the screen is locked after power on. You need to touch the child lock key and enter the initial password (1111). Other operations can only be performed after unlocking is successful.
If the air purifier is set with the function of timing switch for the first time, it will start automatically when it reaches the set starting time of the day, and it will start to work according to the state before the last shutdown.
The screen will automatically enter the state of energy-saving information screen after running for one minute. Touch at any position of the touch screen to light up the screen.
Manual mode
After power on, the default air purifier is in "Manual" mode. At this time, after unlocking, you can touch this button
to manually adjust the fan speed. After setting, the air purifier will operate according to the set gear until manual shutdown. Please note manual shutdown is required in “Manual mode”.
Automatic mode
After unlocking, directly switch to “Automatic” mode by touch this button. After the system enters the automatic mode, the wind speed of the automatic switch and fan shall be adjusted according to the set timing demand and the concentration of the polluted particles.
UV lamp ON/OFF
After unlocking, turn on/off the UV lamp by touching this button
, and when you turn on the UV function, it will turn off after half an hour automatically, and then automatically on after another half hour, and so on, until you manually turn off the UV light. When the UV light is not on, it will not cycle automatically.
Time setting
After long pressing the clock area, the following screen will pop up (pay attention not to press the week area, it will be invalid):
At this time, input the local specific time (accurate to seconds) on the numeric keyboard, and then press enter to complete the time setting:
Real time sensing of the "TVOC", “PM2.5”, “CO2” in the air, the controller displays the data fed back by the sensors on the screen, and then automatically adjusts the fan gear according to the data:
1. In green, the fan runs at the lowest gear;
2. When yellow, the fan runs in the middle gear;
3. When red, the fan runs at the highest gear.
Please note that when any of the three values is detected to exceed the below green value, the fan will automatically increase the gear to operate until all values are within the set green value.
TVOC
0-250ppb: Green
250-500ppb: Yellow
>500ppb: Red
PM2.5
0-50ug/m³: Green
50-100ug/m³: Yellow
>100ug/m³: Red
CO2
0-1000ppm: Green
1000-2000ppm: Yellow
>2000ppm: Red
Body disassembly:
On the front of the machine there is a removable cover plate with four screw holes that can be unscrewed to open the cover plate.
Filter disassembly:
Open the front cover plate to replace the filter directly
The primary filter, HEPA filter used by the air purifier are all consumable materials that need to be replaced. Users need to change them from time to time according to local air quality and service time to ensure that the machine can bring clean and comfortable air.
1. Machine not running: check whether the power supply is normal and whether the power switch is on.
2. Excessive noise: check whether the primary filter is blocked, whether any foreign matter is inhaled into the fan cavity, and whether the machine is deformed or injured.
3. Decrease in filtration efficiency: check whether the high-efficiency filter is damaged or blocked. If it is, replace the filter.