Compact, High‑Efficiency AMC Filtration for Cleanroom Ceilings
The DSX FFU Chemical Filter is a purpose‑built air treatment unit designed for installation inside fan filter units (FFUs) in cleanroom ceilings. It delivers targeted removal of acidic gases, alkaline compounds, condensable VOCs, and dopants – the four major categories of airborne molecular contamination (AMC) that threaten semiconductor yield, pharmaceutical purity, and laboratory accuracy.
Manufactured in our state‑of‑the‑art facility with over 20 years of chemical filtration expertise, this filter combines high adsorptive capacity with low airflow resistance, making it an ideal solution for continuous, energy‑efficient cleanroom operation.
Our FFU chemical filter is effective against a wide spectrum of pollutants, including:
| Category | Examples of Removed Gases/Vapors |
|---|---|
| Acids | Hydrogen cyanide (HCN), hydrofluoric acid (HF), nitric acid (HNO₃), phosphoric acid (H₃PO₄), sulfuric acid (H₂SO₄), acetic acid, nitrogen dioxide (NO₂), sulfur dioxide (SO₂) |
| Bases (Alkalis) | Ammonia (NH₃), N‑methyl‑2‑pyrrolidone (NMP), amines |
| Condensables | Acetone, toluene, siloxanes, plasticizers |
| Dopants | Boric acid, phosphorus compounds, arsenic compounds |
We customize the filter media blend to match your specific pollutant profile, ensuring maximum removal efficiency for your unique environment.
| Feature | Benefit |
|---|---|
| Advanced Media Formulation | High‑capacity adsorbents (activated carbon, ion‑exchange resins, chemisorbent blends) capture both polar and non‑polar contaminants. |
| Low Pressure Drop | Optimized pleat design minimizes fan energy consumption – critical for FFU systems. |
| Modular & Lightweight | Standard sizes fit most FFU housings; easy drop‑in replacement without tools. |
| Customizable Dimensions & Media | Tailored to your FFU model and specific pollutant challenge – contact us for a bespoke solution. |
| Reliable Sealing | Chemical‑free EPDM gaskets and PU sealants eliminate outgassing, ensuring zero cross‑contamination. |
| Long Service Life | High adsorption capacity reduces change‑out frequency, lowering total cost of ownership (TCO). |
| Sturdy Construction | Corrosion‑resistant frame materials (galvanized steel or SS304) withstand harsh cleanroom chemicals. |
Semiconductor & electronics fabs (photolithography, etching, diffusion areas)
Pharmaceutical & biotech cleanrooms (sterile filling, R&D labs)
Hospital operating theatres & isolation wards
University & industrial research laboratories
Any FFU‑based cleanroom requiring AMC control
20+ Years of Chemical Filtration Expertise – Our team masters media blending, manufacturing, and field application engineering.
State‑of‑the‑Art Production – Advanced equipment and strict quality control ensure consistent batch‑to‑batch performance.
Data‑Driven Customization – We test your facility’s air quality and design a filter that precisely targets your pollutants.
End‑to‑End Support – From initial consultation to installation and ongoing maintenance, our professional after‑sales team is always available.
Proven Reliability – Thousands of units installed in leading semiconductor and pharmaceutical plants worldwide.
Contact our technical team today with your FFU specifications and contaminant data. We will deliver a tailor‑made filter that optimizes performance, energy efficiency, and budget – backed by our satisfaction guarantee.
Dynamic Adsorption of DSX Filters for Various Gases
853(2750) filter material - to remove volatile organic compounds, sulfur dioxide, nitrogen dioxide, ozone, sulfur oxide. This filter material is the most effective for removing volatile organic compounds, and it also has a considerable capacity for common outdoor pollutants such as sulfur dioxide, nitrogen dioxide, ozone, sulfur oxide. This filter material is also very effective in removing boron.
875(2751) filter material - used to remove acids such as hydrogen fluoride, hydrofluoric acid, and sulfuric acid. This filter material is also very effective in removing sulfur dioxide, nitrogen dioxide, ozone, and hydrogen sulfide (better filtration effect than 853 filter material).
Both 147 and 875 media can also remove VOCs.However,the capacity (service life) is reducedto 1/2 as compared to 853 media.
Flow rate vs. Pressure Drop

| Filter Type | Cell type | Prefilter type |
| Depth | 11-1/2" or 5-7/8" | 2" or 4" |
| Media | Pleated 863、147、875 | Pleated 863、147、875 |
| No. of Pleat | 10-12 pleats/linear ft | 10-12 pleats/linear ft |
Frame Material:
5-7/8" & 11-1/2" use aluminum.galvanizedsteel,stainless steel.
2"&4"use paper,aluminum,galvanizedsteel,stainless.
Header Design:Single header,double header,box type.
| Media Tpye | VOC(TA) 853(2750) | BASE(AM 147(2752) | ACID(ABE) 875(2751) |
| Thickness | 2.2mm | 2.2mm | 2.2mm |
| Basis Weight | 600g/m2 | 600g/m2 | 600g/m2 |
Service Life NH₃ Ammonia Toluene Hydrogen sulfide Sulfur dioxide | - 75,000 60,000 92,000 | 67,000 41,000 9,000 10,000 | - 57,000 34,000 139,000 |
Guide of Usage | Boron Volatile Organic Compounds (VOC) SO₂ Sulfur Dioxide NO₂ Nitrogen Dioxide Ozone H₂S Hydrogen Sulfide Commo outdoor pollutants Paint odor Tobaccosmoke odors Food Aromas | Ammonia Amines NMP Anima odor Bathroom Smells | Acid Volatile Organic Compounds (VOC) HCl Hydrogen Chloride HF Hydrogen Fluoride H₂SO₄ Sulfuric Acid SO₂ Sulfur Dioxide NO₂ Nitrogen Dioxide Ozone H₂S Hydrogen Sulfide |
These results can be compared by determining the amount of gas,in parts per billion(ppb).adsorbed in the media over the time period measured and expressing the result inppb-hours.Good performance would be found when much of the gas is adsorbed overlong time periods.

Pressure Drop of Competitive Pleated Filters
The pressure drop of DSX filter is lower than that of the filter from Company A.


Comparison of the adsorption capacity of DSX chemical filter and Company B's filter for hydrogen sulfide.The DSX chemical filter has better absorption capacity and efficiency compared to Company B's filter.



The DSX chemical filter has good efficiency for nitrogen dioxide, acetone, hydrogen chloride, and glutaraldehyde.

Product Specifications
| Product name | Flat pleated AMC chemical filter |
| Frame material: | Anodized aluminum extrusion | |
| Protective net: | Double-sided protective net made of baked or treated aluminum mesh | |
| Gasket: | Gaskets made of non-chemically releasing EPDM |
Features of DSX AMC chemical filter
1. High efficiency in removing chemical pollutants, with an initial efficiency of over 95%. | System Installation Diagram |
|
2. High amount of activated carbon coating | ||
3. Low air resistance | ||
| 4. Long service life | ||
| 5. Coated with hollow fiber melt, with activated carbon enclosed within. | ||
| 6. The fine carbon of the coated material uses 60-80 CTC 30-60 mesh coconut shell activated carbon | ||
7. Low dust production | ||
| 8. No chemical release | ||
9. Three types available for removing different pollutants: - MA-ABE: Removes acidic gas (ACID) molecule pollutants - MB-AM: Removes alkaline gas (BASE) molecule pollutants - MC-TA: Removes volatile organic solvent (VOC) molecule pollutants | ||
| 10. Used for MAU with a carbon base weight of 800g/m², and for FFU with a carbon base weight of 600g/m² | ||
| 11. The air conditioning unit is installed between the primary and medium efficiency filters, while the FFU is installed at the air inlet and inside the return air conditioning unit. |
Product introduction
Airflow pressure loss diagram |
|
DSX FFU Chemical Filter parameters (customizable non-standard)
| Dimensions | Air speed | Wind resistance | Dimensions | Air speed | Wind resistance |
| W*H*D(mm) | M/S | (Pa) | W*H*D(mm) | M/S | (Pa) |
| 287*592*50 | 0.5 | 45 | 287*592*70 | 0.5 | 30 |
| 508*508*50 | 0.5 | 45 | 508*508*70 | 0.5 | 30 |
| 592*592*50 | 0.5 | 45 | 592*592*70 | 0.5 | 30 |
| 610*610*50 | 0.5 | 45 | 610*610*70 | 0.5 | 30 |
| 610*915*50 | 0.5 | 45 | 610*915*70 | 0.5 | 30 |
| 531*1131*50 | 0.5 | 45 | 531*1131*70 | 0.5 | 30 |
| 553*1153*50 | 0.5 | 45 | 553*1153*70 | 0.5 | 30 |
| 570*1170*50 | 0.5 | 45 | 570*1170*70 | 0.5 | 30 |
| 600*1200*50 | 0.5 | 45 | 600*1200*70 | 0.5 | 30 |
| 810*1010*50 | 0.5 | 45 | 810*1010*70 | 0.5 | 30 |
| 915*1200*50 | 0.5 | 45 | 915*1200*70 | 0.5 | 30 |
| 1165*1165*50 | 0.5 | 45 | 1165*1165*70 | 0.5 | 30 |
| 1175*1175*50 | 0.5 | 45 | 1175*1175*70 | 0.5 | 30 |
| 1200*1200*50 | 0.5 | 45 | 1200*1200*70 | 0.5 | 30 |
How Often to Replace Air Filters | Expert Guide & Solutions – Deshengxin
How Does an Air Filter Work? – Comprehensive Guide to Air Filtration Technology
What Are the Maintenance Requirements for Air Filter Systems? – Expert Air Quality Solutions
How Do I Choose the Right Air Filter for My Facility? – Expert Air Purification Solutions
Which Industries Benefit Most from Our Air Filter Systems? – Customized Air Purification Solutions
How In-House Production Enhances Air Filter Quality & Pricing – Expert Air Filter Solutions
The Effectiveness of HEPA Filters in Removing COVID-19, Odors, and VOCs
Carbon Filter vs HEPA Filter: Which is Best for Air Purification?
What Are HEPA Filters? Understanding Their Types and Applications