Availability: | |
---|---|
Quantity: | |
DSX-HFC-1040
DSX
OEM, ODM
1 Year
CCC/CE/ISO9001
1. Horizontal Laminar Airflow: Ensures uniform distribution of filtered air across the work surface, creating a sterile environment free of particles and contaminants.
2. High-Efficiency Particulate Air (HEPA) Filters: Effectively removes airborne particles to maintain aseptic conditions for experiments and sample preparation.
3. Ergonomic Design: Offers user comfort and convenience with adjustable settings for optimal working conditions.
4. Versatile Applications: Suitable for tasks such as cell culture, microbiology, and electronics assembly, providing a hygienic workspace for various laboratory procedures.
1. Dust protection: In the manufacturing and assembly processes of electronic devices, strict control of dust and contaminants is essential. Horizontal laminar flow clean benches provide efficient filtration systems and smooth airflow, effectively preventing dust and particles from entering the work area, ensuring the production quality of electronic products and their performance stability.
2. High cleanliness requirements: The electronics industry demands high cleanliness levels in the work environment. Horizontal laminar flow clean benches adopt advanced filtration technology and design to provide clean spaces up to ISO 5 (Class 100) level, meeting the cleanliness standards in the manufacturing of electronic products.
3. Static control: Electronic equipment is susceptible to static electricity during production and assembly processes. Horizontal laminar flow clean benches can be equipped with static elimination devices to reduce the impact of static electricity on electronic devices and components, improving production efficiency and product quality.
4. Flexibility in functionality: Horizontal laminar flow clean benches can be customized according to specific requirements of the electronics industry, such as adding UV lights, HEPA filters, airflow adjustment systems, and other features to meet different application scenarios and production processes.
5. Enhanced work efficiency: By providing a sterile, clean, and stable working environment, horizontal laminar flow clean benches can help electronics manufacturers increase production efficiency, reduce product damage rates, lower maintenance costs, and accelerate time-to-market for products.
1. State-of-the-Art Manufacturing Facilities: Equipped with advanced technology and machinery to ensure precision engineering and quality control.
2. Experienced Team of Engineers and Technicians: Our knowledgeable staff are dedicated to designing and manufacturing high-quality laboratory equipment to meet industry standards.
3. Customization Options: We offer customizable features and specifications to tailor our Horizontal Flow Clean Bench to suit specific laboratory requirements.
4. Strict Quality Assurance: Every Horizontal Flow Clean Bench undergoes rigorous testing and inspection processes to guarantee optimal performance and reliability.
5. Energy Efficiency: Our Horizontal Flow Clean Bench is designed with energy-saving features to minimize power consumption while maintaining high-performance airflow and cleanliness standards.
6. Compact Design: The space-saving design of our Horizontal Flow Clean Bench allows for easy integration into existing laboratory setups without compromising on functionality or performance.
7. Easy Maintenance: With user-friendly maintenance procedures and easily accessible components, our Horizontal Flow Clean Bench ensures hassle-free upkeep and longevity.
8. Competitive Pricing: Despite the advanced features and high-quality construction, our Horizontal Flow Clean Bench is competitively priced, offering excellent value for our customers.
9. Regulatory Compliance: Our Horizontal Flow Clean Bench meets industry regulations and safety standards, providing peace of mind for laboratory professionals and researchers.
10. Technical Support and Customer Service: Our factory's commitment to providing exceptional technical support and customer service ensures a smooth purchasing experience and ongoing support for our customers.
DSX Horizontal Flow Clean Bench is the ideal choice for laboratories seeking a reliable, efficient, and cost-effective solution for creating a controlled and sterile working environment.
Premium Quality, Stylish Design, Competitive Price - Meets All Your Needs
☑ CE certificated,widely used in laboratory,etc;
☑ Horizontal and vertical laminar flow optional;
☑ Single,double and three person type optional;
☑ Standard and customized size as per requirement;
☑ Efficient motor and long service life HEPA filter to save operation cost;
☑ High-quality case material to ensurestrength and elegant appearance.
Scientific structure
The downward positive pressure airflow can prevent unfiltered outside air from entering the operating area; optional movable detachable SUS304 stainless steel countertop, no vibration influence.
High cleanliness
High-quality filter paper, filtration efficiency 99.99% @(0.3UM), ensuring purification effect
Long service life
Equipped with DSX high-quality low-noise centrifugal fan, it can run continuously for a long time, and the equipment has a longer service life.
Comfortable Operation
- The LED daylight lamp is designed to illuminate from behind, increasing work brightness, without glare or eye strain, reducing eye fatigue for operators.
Real-time monitoring
Optional LCD touchscreen, pressure gauge, real-time monitoring of its working status, adjusting air volume, sterilization time, simple and fast.
Horizontal flow clean bench parameters
Item No.
| DSX-HF-995 | DSX-HF-1300 | DSX-HF-1605 | DSX-HF-1910 | ||
size | W (w1)mm | 995(915) | 1300(1220) | 1605(1525) | 1910(1830) | |
D (D1)mm | 850(550) | 850(550) | 850(550) | 850(550) | ||
H (H1)mm | 1480(610) | 1480(610) | 1480(610) | 1480(610) | ||
volume(M3/h) | 905 | 1250 | 1550 | 1850 | ||
velocity(m/s) | 0.45±20% | |||||
Cleanness | CLASS100 | |||||
HEPA Efficiency | 99.99%(0.3um) | |||||
HEPA Size | 915*610*70 | 1220*610*70 | 915*610*70 610*610*70 | 915*610*70 | ||
HEPA quantity | 1 | 1 | 1/1 | 2 | ||
Work table material | Sanding stainless steel | |||||
Noise | <58db | <58db | <60db | <62db | ||
Noise test position | 20cm in front of clean bench, 1.2m to the floor | |||||
Power | 160W | 180W | 260W | 280W | ||
Person | 1 | 1~2 | 2~3 | 3~4 | ||
Power supply | 230ACV—50Hz |
Single operation vertical flow clean bench parameters (all products can be customize)
Item No.
| DSX-S-1040 | DSX-S-1340 | DSX-S-1640 | DSX-S-1950 | ||
Size | W (w1)mm | 1040(950) | 1340(1250) | 1640(1550) | 1950(1860) | |
D (D1)mm | 740(645) | 740(645) | 740(645) | 740(645) | ||
H (H1)mm | 2050(800) | 2050(800) | 2050(800) | 2050(800) | ||
Volume(M3/h) | 905 | 1350 | 1650 | 1950 | ||
velocity(m/s) | 0.45±20% | |||||
cleanness | CLASS100 | |||||
HEPA Efficiency | 99.99%(0.3um) | |||||
HEPA size | 915*610*70 | 1220*610*70 | 915*610*70 610*610*70 | 915*610*70 | ||
HEPA quantity | 1 | 1 | 1/1 | 2 | ||
PRE FILTER size | 495*495*45/paper | 595*595*45/ paper | 495*495*45/ paper | |||
PRE FILTER quantity | 1 | 1 | 1 | 2 | ||
Vibration half peak value | Work table and clean bench frame is separate, no effect on vibration | |||||
Work table material | Sanding stainless steel | |||||
Noise | <58db | <58db | <60db | <62db | ||
Noise test position | 20cm in front of clean bench, 1.2m to the floor | |||||
Power | 160W | 180W | 260W | 280W | ||
Person | 1 | 1~2 | 2~3 | 3~4 | ||
Power supply | 230ACV—50Hz |
Double side vertical flow clean bench parameters
Item No. | DSX-D-1340 | DSX-D-1640 | DSX-D-1950 | |
Size | W (w1)mm | 1340(1340) | 1640(1640) | 1950(1950) |
D (D1)mm | 1450(1350) | 1450(1350) | 1450(1350) | |
H (H1)mm | 2050(800) | 2050(800) | 2050(800) | |
volume(M3/h) | 2500 | 3200 | 3700 | |
velocity(m/s) | 0.45±20% | |||
Cleanness | CLASS100(USA Federal Standard209E) | |||
HEPA Efficiency | 99.99%(0.3um) | |||
HEPA Size | 122*610*70 | 915*610*70 610*610*70 | 915*610*70 | |
HEPA quantity | 2 | 2/2 | 4 | |
PRE FILTER size | 495*495*45/paper | 595*595*45/ paper | 495*495*45/ paper | |
PRE FILTER quantity | 2 | 2 | 4 | |
Vibration half peak value | Work table and clean bench frame is separate, no effect on vibration | |||
Work table material | Sanding stainless steel | |||
Noise | <60db | <62db | <62db | |
Noise test position | 20cm in front of clean bench, 1.2m to the floor | |||
Power | 360W | 520W | 560W | |
Person | 2~4 | 4~6 | 6~8 | |
Power supply | 230ACV—50Hz |
Semiconductor manufacturing
Aerospace
Laboratory
Electronics manufacturing
Precision machinery
Lithium electric manufacturing
Food Processing
Hospital
Clean room
Optics
Cosmetics production
Industry of fine chemicals